Impact Factor: 1.4

Article

Clinical case

REC Interv Cardiol. 2019;3:198-199

The difficulty of interventional cardiology in routine everyday practice. Paying the price of a sigh

La dificultad de la cardiología intervencionista en el trabajo diario: el precio de un suspiro

Jessica Roa Garrido, Antonio E. Gómez Menchero, Rosa Cardenal Piris, Santiago Camacho Freire, Marcos López Rojas, and José F. Díaz Fernández

Unidad de Hemodinámica y Cardiología Intervencionista, Unidad de Gestión Clínica de Cardiología, Hospital Juan Ramón Jiménez, Huelva, Spain

See related content

The difficulty of interventional cardiology in routine everyday practice. Paying the price of a sigh. How would I approach it?
Eduardo Pinar Bermúdez

The difficulty of interventional cardiology in routine everyday practice. Paying the price of a sigh. Case resolution
Jessica Roa Garrido, Antonio E. Gómez Menchero, Rosa Cardenal Piris, Santiago Camacho Freire, Marcos López Rojas, and José F. Díaz Fernández

CASE PRESENTATION

We hereby present the case of a 73-year-old male with a past medical history of high blood pressure, diabetes mellitus type 2, dyslipidemia, and former smoker as cardiovascular risk factors. The patient showed chronic ischemic heart disease that started as unstable angina with coronary artery disease of the right and circumflex coronary arteries, undergoing complete percutaneous revascularization in 2008 with everolimus-coated stents.

Ten years later the patient suffered from a non-ST segment elevation acute coronary syndrome of inferior location with low blood pressure and need for vasoactive amines, which is why he was transferred to the cath. lab for an early invasive strategy.

The diagnostic coronary angiography performed using the right radial access showed the presence of a plaque complicated with a thrombus in the ostium of the right coronary artery with Thrombolysis in Myocardial Infarction grade flow 3 (figure 1).

Figure 1. Acute complicated lesion in the ostium of the right coronary artery.

A 6-Fr JR guiding catheter and a Sion guidewire (Asahi) were selected for the procedure. Predilatation was attempted with a 3.5 × 10 mm noncompliant balloon (figure 2) and a 3.5 × 18 mm Orsiro sirolimus-eluted stent was implanted covering the ostium (figure 3).

Figure 2. Predilatation with one 3.5 × 18 mm noncompliant balloon inflated at 14 atm, with adequate expansion.

Figure 3. Angiography prior to the implantation of the stent adjusted to the ostium of the right coronary artery.

When the stent was deployed and inflated at 6 atm, with the patient in a state of agitation given his hemodynamic situation, he took a deep breath that caused the displacement of the stent towards the aorta (figure 4), that was deployed completely outside the ostium of the right coronary artery.

Figure 4. Stent displaced towards the aorta is observed. The arrow shows the mark of calcium in the sinus of Valsalva.

Therefore, we found ourselves with one under-expanded, displaced or loose stent inside the aorta that made maneuverability difficult with an uncovered thrombus in a complex ostial lesion and in the clinical context of an acute coronary syndrome.

Corresponding author: Unidad de Hemodinámica y Cardiología Intervencionista, Hospital Juan Ramón Jiménez, Ronda Norte s/n, 21005 Huelva, Spain.
E-mail address: jroa.garrido@gmail.com (J. Roa Garrido).

Editorials

Recic Uk 23 087 F2

Original articles

Recic 23 026 Uk F1

Editorials


Original articles

Recic 23 007 Uk F1
Recic Uk 23 053 F3
Recic Uk 23 042 F3

Debate

Debate: Asymptomatic severe aortic stenosis: when should we intervene?

Recic 23 082 F1
Recic 23 083 F1