Evolut R implantation in Perceval bioprosthesis with periprosthetic leakage

Implante de Evolut R en bioprótesis Perceval con insuficiencia periprotésica. ¿Cómo lo haría?

Ramiro Trillo NoucheThis email address is being protected from spambots. You need JavaScript enabled to view it., Fernando Gómez Peña, Diego López Otero, Xoan Carlos Sanmartín Pena, Ana Belén Cid Álvarez and José Ramón González Juanatey

Unidad de Cardiología Intervencionista, Servicio de Cardiología, Complejo Hospitalario Universitario de Santiago de Compostela, Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIVERCV), Santiago de Compostela, A Coruña, España

See related content

Evolut R implantation in Perceval bioprosthesis with periprosthetic leakage. How would I approach it?
Pablo Avanzas

Evolut R implantation in Perceval bioprosthesis with periprosthetic leakage. Case resolution
Ramiro Trillo Nouche, Fernando Gómez Peña, Diego López Otero, Xoan Carlos Sanmartín Pena, Ana Belén Cid Álvarez, José Ramón González Juanatey

Presentation of the case

We hereby present the case of an 83 year old hypertense, diabetic male patient with asymptomatic severe aortic stenosis, preserved ventricular function, mild mitral regurgitation and no coronary artery disease.

He had low-intermediate surgical risk (3.1% in the Society of Thoracic Surgeons scoring system) and, in medical-surgical session, it was decided to proceed with the surgical replacement of his aortic valve.

Perceval Sutureless Aortic Heart Valve, Sorin size L was implanted. The follow-up echocardiogram prior to hospital discharge showed an aortic transvalvular gradient of 22/11 mmHg and 2 periprosthetic regurgitation jets indicative of mild-to-moderate aortic failure with pulmonary artery systolic pressure of 40 mmHg.

Five months after valvular replacement, the patient was hospitalized due to acute heart failure with acute pulmonary edema. During the physical examination, the auscultation showed murmurs indicative of grade III/IV aortic regurgitation and bilateral pulmonary rales. The echorcardiogram showed severe aortic failure due to the lack of stent coverage of the aortic bioprosthesis at the level of the aortic annulus and in the area corresponding to the non-coronary sinus and most of the right coronary sinus which conditioned 2 regurgitation jets towards the left ventricle that appeared slightly dilated. The left ventricular ejection fraction was somehow depressed. Both mitral regurgitation and pulmonary hypertension were categorized as severe being the pulmonary artery systolic pressure, 60 mmHg.

Conflicts of interest

R. Trillo Nouche is proctor for Medtronic.

Corresponding author: Servicio de Cardiología, Complejo Hospitalario Universitario de Santiago de Compostela, Rúa da Choupana s/n, 15706 Santiago de Compostela, A Coruña, Spain.
E-mail address: This email address is being protected from spambots. You need JavaScript enabled to view it. (R. Trillo Nouche).

Review Article

Recic 19 3 061 F3

Original Articles

Recic Uk 19 3 056 F3

Alfonso Jurado-Román, José Manuel Montero-Cabezas, et al.

Recic Uk 19 3 024 F2

Jorge Solano-López Morel, José A. Fernández-Díaz, et al.

Editorials

Clinical trial review

Special article

The difficulty of interventional cardiology in routine everyday practice. Paying the price of a sigh

Jessica Roa Garrido, Antonio E. Gómez Menchero, et al.

How would I approach it?
Eduardo Pinar Bermúdez

Case resolution
Jessica Roa Garrido, Antonio E. Gómez Menchero,

Editorial

Clinical trial review

Letters to the Editor

Recic 19 3 060 F1

Images in Cardiology

Recic 18 3 030 F3